The Enterovirus RNA Real-Time PCR kit coded ENTERORNA.CE is intended for the qualitative detection of Enterovirus RNA in human plasma and CSF samples (Cerebral Spinal Fluid) with a simultaneous control of the amplification reaction through an Internal Control (IC).
The JCV DNA Quantitation Real-Time PCR kit coded JCVDNAQT.CE is intended for the quantitative detection of the JC Virus DNA in human plasma ,urine and cerebrospinal fluid (CSF) with a simultaneous control of the amplification/extraction reaction through an Internal Control (IC).
The BKV DNA Quantitation Real-Time PCR kitcoded BKVDNAQT.CE is intended for the quantitative detection of the BK Virus DNA in human plasma and urine with a simultaneous control of the amplification/extraction reaction through an Internal Control (IC). The kit has been adapted for the use on the Real-Time Thermacyclers ABI 7500 Sequence Detection System® (Software SDS version 1.3.1, Applied Biosystems™*) or Miniopticon® (Software CFX manager version 1.6, Biorad™**) or MX3000P® (Software MxPro version 4.01, Stratagene™***).
The VZV DNA Quantitation (QT) Real-Time PCR kit coded VZVDNAQT.CE is intended for the quantitative detection of Varicella-Zoster virus DNA in human plasma and CSF (cerebrospinal fluid) with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC).
The EBV DNA Quantitation (QT) Real-Time PCR kit coded EBVDNAQT.CE is intended for the quantitative detection of Epstein-Barr Virus DNA in human plasma and whole blood collected in EDTA with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC).
The HHV8 DNA Quantitation (QT) Real-Time PCR kit coded HHV8DNAQT.CE is intended for the quantitative detection of Human herpesvirus 8 DNA in human plasma/blood with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC).
The HHV6 DNA Quantitation Real-Time PCR kit coded HHV6DNAQT.CEis intended for the quantitative detection of the Herpesvirus 6 DNA in human plasma/blood with a simultaneous control of the amplification/extraction reaction through an Internal Control (IC).
The HSV2 DNA Quantitation (QT) Real-Time PCR kit coded HSV2DNAQT.CE is intended for the quantitative detection of Human herpes simplex virus 2 DNA in human plasma and CSF (cerebrospinal fluid) with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC).
The HSV1 DNA Quantitation (QT) Real-Time PCR kit coded HSV1DNAQT.CE is intended for the quantitative detection of Human herpes simplex virus 1 DNA in human plasma and CSF (cerebrospinal fluid) with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC).
The CMV DNA Quantitation (QT) 2nd Generation Real-Time PCR kit coded CMVDNAQT.2G.CE is intended for the quantitative detection of Cytomegalovirus DNA in human sample (blood, plasma, amniotic fluid) with a simultaneous control of the extraction/amplification reaction through an Internal Control (IC). CMVDNAQT.2G.CE assay was standardised against the 1st WHO International Standard for HCMV (NIBSC code 09/162) to express samples concentration also in International Unit (IU/ml).
The RNA Retrotrascription kit coded RNART.CE is intended for the reverse transcription to cDNA of highly purified RNA coming from Virus (vRNA) with Random Hexamers. Reverse transcription polymerase chain reaction (RT-PCR) is aimed to the generation of many copies of a cDNA from an RNA molecule using the enzyme Reverse Transcriptase. The resulting cDNA can be use as template of a traditional or real-time PCR.